I believe that engineers are not unfamiliar with network analyzers. Have you encountered network analyzer failures in daily use?Agitek service shares common faults in network analyzer maintenance.
1. power failure
When the network analyzer is repaired, the power failure usually manifests as: the power indicator on the front panel does not light up, the fan does not rotate, the instrument cannot be started normally, or the power supply voltage is unstable, which causes the spectrum analyzer to keep resetting, and the signal power is low due to low analog voltage.
2. Display failure
Display failures usually manifest as: no display (black screen), blurry screen, and gray-white display. Display failure may be caused by the failure of the display itself, the failure of the graphics processing board or the failure of the CPU.
3. Local oscillator failure
LO faults are usually manifested as: LO loss of lock, large signal insertion loss caused by low LO power, and poor LO spectral purity.
4. Signal path failure
When the network analyzer is repaired, the signal path faults usually manifest as: input connector faults, signal cable faults, attenuator faults, preselector faults, inverter faults, intermediate frequency amplification/filtering faults, data acquisition and processing faults.
5. Processor failure
When the network analyzer is repaired, the processor failure is usually manifested as: processor hardware and program failure. Due to the high reliability of the processor hardware, in most cases, the processor failure is a program (software) failure.
If your instrument has the above failure
Welcome to contact Agitek service
Professional maintenance equipment various fault problems ~
The above are the common faults of network analyzers shared by Agitekservice (www.agitekservice.com), I hope it can be helpful to everyone. For more information, please leave a message on the website for consultation. We have professional customer service and maintenance engineers to serve you!
Agitekservice was established in 2008. Specializing in the maintenance and technical support of various test and measurement instruments and test systems, he is good at network analyzer maintenance and other technologies, and has the technical ability to perform chip-level maintenance of high-end instruments at home and abroad. Since its establishment, it has closely followed the pulse of instrument technology development, closely followed the development trend of electronic devices and PCB technology, and has always maintained leading maintenance technology and capabilities. After years of accumulation, dozens of imported and domestic brands, various types of testing and measuring instrument maintenance capabilities have been formed. Since its establishment, it has closely followed the pulse of instrument technology development, closely followed the development trend of electronic devices and PCB technology, and has always maintained leading maintenance technology and capabilities. After years of accumulation, it has formed dozens of imported and domestic brands such as Tektronix oscilloscopes and Keysight (formerly Agilent, HP) RF instruments, covering Fluke, Keithley, Rohde & Schwarz and Anritsu. , Various types of test and measurement equipment maintenance capabilities.