Agilent data collector 34970A maintenance communication cannot be connected

Time:2022-12-01             Xi'an Agitek spectrometer maintenance center    4798

  Agilent data collector 34970A maintenance communication is not connected, and Aetna maintenance detection is actually not connected. This issue will share the Agilent data collector 34970A instrument maintenance case.

  Recently, our company received an Agilent data collector 34970A maintenance instrument from an organization in Anhui. When we opened the package of the Agilent data collector, we found that the appearance of the Agilent data collector was quite good. After careful investigation by the engineers in the agitekservice Instrument Rental/Maintenance Center, we would like to introduce the maintenance, product introduction and product performance of the Agilent data collector!

  1、 Maintenance of Agilent data collector 34970A:

  Agilent data collector maintenance model: 34970A;

  Fault reported: communication cannot be connected, an ERROR error occurs on the machine, and a module 34901A is broken;

  Fault detection: the 34401A module of the instrument was damaged, causing restart, and no error was found;

  Maintenance measures: replace the 34401A module and adjust the testing instrument!

  After the comprehensive inspection of Aetna Maintenance Engineer Chem, it was confirmed that there was no problem with Agilent network analyzer after maintenance. During the maintenance process, the microwave switch was replaced, the port power was adjusted, and the communication was normal after comprehensive repair. The quality inspection and test indicators were normal. After the secondary quality inspection was qualified, the instrument was cleaned, the fragile label of the instrument was pasted, and the maintenance report was generated and returned to the customer. When the above problems occur with our instruments, we must find a professional and reliable Agilent Network Analyzer Maintenance Center like Wuhan agitekservice Instrument for after-sales maintenance!

  2、 Product introduction of Agilent data collector:

  Agilent 34970A Data Collector Origin: Agilent Agilent, USA Manufacturer: Agilent, 3-slot data acquisition and switch host, 61/2 (22 bit) built-in DMM, 11 internal measurement functions, 8 switch and control plug-in modules, including Agilent BenchLink data recorder software. Agilent 34970A is a high-performance, low-cost data acquisition and switch host, and is very suitable for data recording Data acquisition and general switching and control applications, Agilent 34970A data collector.

  3、 Product performance of Agilent data collector:

  ·3-slot host with built-in 6% digital multimeter and 8 kinds of switches and control plug-in modules: it can measure and convert 11 different input signals: temperature (thermocouple, RTD and thermistor): DC/AC voltage, 2-wire and 4-wire resistance frequency and cycle: DC/AC current;

  ·1Gbit LANUSB (34972A) GPIB and RS · 232 interface (34970A) can easily connect to your PC! The graphical Web interface allows you to perform monitoring and control (34972A) by clicking. Without a PC, the USB memory supports downloading configuration and recording data (34972A);

  ·BenchLink Data Logger software is included, which can be configured and controlled for testing. Display measurement results and collect data for further analysis

  The above is the case that Agilent data collector 34970A communication is not connected to the maintenance, which was explained by the small editor of Aetna Instrument Rental/Maintenance Center. For details of other Agilent data collector maintenance cases, continue to pay attention to Aetna's maintenance instrument network. If you have similar instrument maintenance needs, you can visit Aetna Maintenance Network at any time. We have a professional team of original engineers to provide you with considerate service!

  Wuhan agitekservice Testing Equipment Maintenance Co., Ltd. was established in 2008. The maintenance of domestic instruments is trapped in the monopoly of foreign large factories, which is difficult to overcome in terms of technology. Try again and explore again and again. With the tireless research of the engineer team day and night, we have broken the original technical barriers of the big factory. We can also complete the chip level maintenance of the test Agilent data collector, which can help customers effectively reduce the cost of instrument maintenance! More Agilent data collector maintenance issues, and continue to pay attention to Wuhan agitekservice Instrument Rental Maintenance Center!

  At present, Aetna Testing Equipment Maintenance Co., Ltd. has equipped various types of hardware testing equipment and professional integrated device maintenance platforms, and is especially good at various testing instrument maintenance, not limited to Tektronix, Agilent, Fluke, Jishili, R&S, Puyuan and other well-known domestic and foreign brands of electrical testing instruments. It can not only help customers greatly reduce the cost of instrument maintenance, but also provide users with various value-added services, including factory repair. Including instrument leasing and second-hand business. If you have any problems with your instrument or need to lease or purchase the instrument, you can contact Aetna Maintenance to help you solve them wholeheartedly!