Product
Case
`
News
NToll-free Hotline
400-8765512
Chinese
Home
Company
Instrument
Spectrum analyzer
RF Signal Source Repair
Network Analyzer
Oscilloscope Repair
Source Meter Repair
Power Amplifier Repair
Dynamic Signal Analyzer Repair
Frequency Meter/Impedance Analyzer/Logic Analyzer Repair
Data acquisition / digital mul
Calibrator Repair
Thermal Imager
Source And Load
The Attachment
Rental / used instruments
Oscilloscope
Spectrum Analyzers
Network Analyzer
Signal Generators
Electronic loads
Other Ieased
Instrument rental center
I want to repair
Maintenance service
Maintenance case
Maintenance
Company news
Technical articles
Download
Order query
Medical Center
Contact
Hello, welcome to Xi 'an Agitek Service!
Instrument Maintenance
|
Rental/Used Instruments
|
I Need Repairs
|
Contact us
|
Service Centre
|
Chinese
Home
About Us
Instrument Maintenance
Spectrum analyzer
RF Signal Source Repair
Network Analyzer
Oscilloscope Repair
Source Meter Repair
Power Amplifier Repair
Dynamic Signal Analyzer Repair
Frequency Meter/Impedance Analyzer/Logic Analyzer Repair
Data acquisition / digital mul
Calibrator Repair
Thermal Imager
Source And Load
The Attachment
Rental/Used Instruments
Oscilloscope
Spectrum Analyzers
Network Analyzer
Signal Generators
Electronic loads
Other Ieased
Instrument rental center
I Need Repairs
Service Centre
Maintenance case
Maintenance
Company news
Technical articles
Download
Order query
Contact Us
Previous
Next
Maintenance service
Agitek maintenance
Maintenance case
Maintenance
Company news
Technical articles
Download
Disassembly photo
Oscilloscope Repair
Signal Generator Repair
digital multimeter
other
Product manual
oscilloscope
Signal generator
Order query
Maintenance case
Maintenance
Company news
Technical articles
Download
Disassembly photo
Oscilloscope Repair
Signal Generator Repair
digital multimeter
other
Product manual
oscilloscope
Signal generator
Order query
Popular Instrument Repair
Keithley 2611B Source Met...
Agilent signal generator ...
Maintenance of Tektronix ...
Maintenance of Tektronix ...
More Instrument Maintenance
Recommended service
Equipment Maintenance
Equipment Ieasing
Used Instrument Sales
Instrument Maintenance Service
Current location:
Home
>
Maintenance service
>Maintenance case
Keysight spectrum analyzer maintenance--N9030A startup error case
Time:2021-03-18
2193
近期安泰仪器维修中心接修一台N9030A频谱分析仪,下面跟着一起看看这台仪器的简单维修流程:
一、故障现象:
10db及以上衰减功率不准;开机报错Error finding operating system, operating system not found
二、检测过程
收到仪器后首先确定仪器是否已经过了原厂质保,经查询该台仪器已经过保。开机提示error load operating system。经检测,仪器硬盘损坏,造成开机不进入系统;开机后自检报错,两个衰减器损坏,造成功率测量超差;YTF损坏,造成3G以上测量低5-10dB。
三、维修过程
维修:更换硬盘,重新安装固件,恢复系统;更换两组衰减器组件,更换YTF组件。
整机调整检测仪器。以上有关
频谱分析仪维修
案例由西安安泰仪器维修中心网整理发布,更多有关仪器维修知识欢迎访问安泰维修中心网(
www.agitekservice.com
)
Last:
Keysight N5182A Signal Generator Repair Different Failure Cases
Next:
Agilent/Keysight N5183A signal generator does not start maintenance
I want to repair
I want to rent instruments
Buy second-hand instruments
Popular article recommendation
1.What is the difference between network analyzer and spectrum analyzer?
2.How to speed up the startup of spectrum analyzer?
3.Common types, characteristics and functions of signal generators
4.20% discount for signal source/network analyzer maintenance unlevel faults
5.Look here! 20% off Keithley Source Watch Repairs!
Related articles recommended
1. Boonton 4500B cannot be started after maintenance
2. Agilent oscilloscope DSO9054H can not boot maintenance
3. FILR thermal imager T640 maintenance [Aetna maintenance]
4. Keithley Source Meter 2400-C Repair [Agitek Service]
5. Stanford Digital Lock-in Amplifier SR830 Repair - Agitek Service
Tel
Map
QQ
Ask
Top