Agitek Service
Agitek instrument maintenance center

NToll-free Hotline400-8765512

Hello, welcome to Xi 'an Agitek Service!      Instrument Maintenance | Rental/Used Instruments | I Need Repairs | Contact us | Service Centre | Chinese

Current location:Home>Instrument>Spectrum analyzer

    Repair of N9020B Spectrum Analyzer

    N9020B spectrum analyzer repair, repair N9020B spectrum analyzer, spectrum analyzer maintenance

    N9020B spectrum analyzer maintenance repairable faults:
    1. The N9020B spectrum analyzer cannot be turned on normally after maintenance
    2. The N9020B spectrum analyzer reports an error when it is repaired and starts, self-checking and self-calibration fail
    3. The N9020B spectrum analyzer is repaired and the measurement level is out of tolerance and the amplitude is abnormal
    4. Other problems of N9020B spectrum analyzer maintenance

    Repair of N9020B Spectrum Analyzer


    Main technical indicators of N9020B spectrum analyzer maintenance
    N9020B MXA Signal Analyzer, Multi-Touch, 10 Hz to 50 GHz
    Frequency 10 Hz to 50 GHz
    Frequency Options 3.6, 8.4, 13.6, 26.5, 32, 44, 50 GHz, Mixers to 1.1 THz
    Maximum analysis bandwidth 160 MHz
    Bandwidth options 25 MHz standard, 40, 85, 125, 160 MHz
    Maximum real-time bandwidth 160 MHz
    Real-time bandwidth options 85, 125, 160 MHz
    DANL -172 dBm at 1 GHz
    Phase noise -114 dBc/Hz at 10 kHz offset at 1 GHz
    Phase noise -114 dBc/Hz at 30 kHz offset at 1 GHz
    Phase noise -136 dBc/Hz at 1 MHz offset at 1 GHz

    N9020B Spectrum Analyzer Repair Description
    Quickly adapt to the evolving test requirements of wireless devices
    Reduce test time with hardware-accelerated power measurement, fast display update rate, and feature marker peak search and fast sweep
    X-Series application software provides one-button measurement, greatly simplifying testing
    Full-band real-time spectrum analysis to capture infrequent or transient signals

    Agitek Service Spectrum Analyzer Repair Repairable Models:

    N9000 series:

    N9320B     N9322C     N9320A     N9340B     N9342C     N9343C     N9344C     N9051A     N9077A     N9080A     N9082A     N9010A     N9020A     N9030A    N9000A     N9041B     N9040B     N9030B     N9020B     N9010B     N9000B     N9038A ;
    Wait until the Agilent/Keysight series have expired warranty period for spectrum analyzer repair.


    N9020B Spectrum Analyzer Repair Procedure:
    Provide testing and quote after testing;
    If the user agrees to the maintenance, the maintenance will be started after the agreement is confirmed;
    If the user disagrees, return to the instrument.
    Maintenance advantages: short maintenance cycle, low price, and provide warranty service at the same time;
    Quality Assurance: After the repair, it is qualified by the measurement unit, and the "Measurement Certificate" is issued.



    Repair of N9020B Spectrum Analyzer

      About us:
      Xi'an Agitek Service was established in 2008, specializing in the maintenance and technical support of various test and measurement instruments and test systems, especially good at spectrum analyzer maintenance, spectrum analyzer maintenance, vector network analyzer maintenance, vector network maintenance, RF source maintenance and other maintenance . Possess the technical ability to perform chip-level maintenance on high-end instruments at home and abroad. Since its establishment, it has closely followed the pulse of instrument technology development, closely followed the development trend of electronic devices and PCB technology, and always maintained advanced maintenance technology and capabilities. After years of accumulation, dozens of imported and domestic brands, various types of testing and measuring instruments maintenance capabilities have been formed.

        Professional Guarantee Strength Service
      ※Agitek Service spectrum analyzer maintenance, professional maintenance, services all over the country
      ※Agitek Service spectrum analyzer maintenance, professional equipment, escort the quality of maintenance
      ※Agitek Service spectrum analyzer maintenance, component-level maintenance, minimize maintenance costs
      ※Agitek Service spectrum analyzer maintenance, maintenance around you, efficient and fast, saving you precious time
      ※Agitek Service spectrum analyzer maintenance does not charge any testing fees, allowing you to fully control the maintenance initiative

      ※Agitek Service spectrum analyzer maintenance, professional technical team, provides all-round technical services for test and measurement instruments


      Contact information:
      Xi'an Agitek Instrument Repair Center
      Headquarters address: C608, Zhicheng Business, No. 17, Gaoxin 4th Road, High-tech Zone, Xi'an City
      Company official website:www.agitekservice.com