N9344C Spectrum Analyzer Repair
N9344C Spectrum Analyzer Repair
N9344C spectrum analyzer repair repairable spectrum analyzer failure:
1. The N9344C spectrum analyzer cannot be turned on normally after maintenance
2. The N9344C spectrum analyzer reports an error during startup, self-test, and self-calibration failure
3. The N9344C spectrum analyzer is repaired and the measurement level is out of tolerance and the amplitude is abnormal
4. Other maintenance problems of N9344C spectrum analyzer
A corner of the N9344C spectrum analyzer repair center:
Main technical indicators of N9344C spectrum analyzer maintenance
N9344C Handheld Spectrum Analyzer (HSA), 20 GHz
Frequency 9 kHz to 20 GHz
Maximum Analysis Bandwidth None
Bandwidth option 3 MHz
DANL -144 dBm at 1 GHz
Phase noise at 10 kHz offset at 1 GHz None
Phase noise at 1 MHz offset -119 dBc/Hz at 1 GHz
Overall amplitude accuracy ±1.3 dB
Third Order Intercept (TOI), +11 dBm at 1 GHz
Maximum third-order dynamic range 96 dB at 1 GHz
Main Features and Functions of N9344C Spectrum Analyzer Maintenance
Get performance designed for field use: Portable and durable, fanless design; clear picture day or night; 4-hour battery life
Comparable performance to benchtop instruments: –144 dBm DANL, ±1.3 dB amplitude accuracy, and < 0.95 s full span sweep time
Innovative task manager reduces test setup time by 95% and automates field testing
N9344C Spectrum Analyzer Repair Repairable Models:
N9000 series:
N9320B、N9322C、N9320A、N9340B、N9342C、N9343C、N9344C、N9051A、N9077A、N9080A、N9082A、N9010A、N9020A、N9030A、N9000A、N9041B、N9040B、N9030B、N9020B、N9010B、N9000spectrum instrument maintenance.
N9344C spectrum analyzer maintenance procedures:
Provide testing and quote after testing;
If the user agrees to the maintenance, the maintenance will be started after the agreement is confirmed;
If the user disagrees, return to the instrument.
Agitek spectrum analyzer maintenance advantages: short maintenance cycle, low price, and provide warranty services;
Quality Assurance: After the repair, it passes the measurement of the unit of measurement and passes the measurement, and issues a "Measurement Qualification Certificate".
About us:
Xi'an Agitek Maintenance Center was established in 2008, specializing in the maintenance and technical support of various test and measurement instruments and test systems, especially good at spectrum analyzer maintenance, spectrum analyzer maintenance, vector network analyzer maintenance, vector network maintenance, RF source maintenance, etc. repair. Possess the technical ability to perform chip-level maintenance on high-end instruments at home and abroad. Since its establishment, it has closely followed the pulse of instrument technology development, closely followed the development trend of electronic devices and PCB technology, and always maintained advanced maintenance technology and capabilities. After years of accumulation, dozens of imported and domestic brands, various types of testing and measuring instruments maintenance capabilities have been formed.