一、E8363A Network Analyzer Rental/Used
Instrument Name: keysight E8363A PNA Series Network Analyzer, 45 MHz to 40 GHz
Instrument brand: keysight
二、Main technical indicators of E8363A network analyzer rental/used
PNA now with 256MB RAM 45 MHz to 40 GHz 123 dB dynamic range at test port 138 dB dynamic range with direct access to receiver 110 dB dynamic range at test port at 40 GHz Sweep speed < 26 μs/point COM/ DCOM and SCPI programming supports TRL/LRM calibration
describe
The Keysight E8363A vector network analyzer is a member of the PNA family of network analyzer platforms, featuring high speed and precision to meet the demanding test requirements of today's high-frequency, high-performance components. The PNA series offers fast sweep speeds, wide dynamic range, low trace noise, and flexible connectivity to meet a variety of test challenges.
The E8363A provides TRL/LRM calibration (using quad receivers) for waveguide, on-wafer and in-fixture devices, optional source attenuator, bias tees and direct receiver access for active device and extended dynamic range measurements .
Powerful automation and self-help tools make the instrument well suited to R&D and manufacturing needs.
三、Why choose Aetna maintenance for network analyzer rental/second-hand?
1. Free Shipping
The company can provide free pick-up and delivery (only in Xi'an urban area), and foreign customers can mail for free;
2. Rental discount
The rent can be given different discounts according to the length of the lease period and the value of the equipment;
3. Technical support
Our company can debug instruments and provide technical guidance according to customer requirements;
4. Provide free laboratory debugging
For customers with short-term rental needs, we can provide a spacious and comfortable testing laboratory free of charge, equipped with the required instruments according to the needs of customers, and charge per time per day. Not only does it have on-site guidance from professional engineers, but it also saves costs!
5. Types of instruments available for sale/rental
Rental/used spectrum analyzer, oscilloscope, radio comprehensive tester, network analyzer, modulation degree tester, audio analyzer, logic analyzer, synthetic signal source, function signal source, microwave signal source, high and low frequency sweeper, withstand voltage Tester, power meter, distortion meter, frequency meter, microwave frequency meter, AC/DC stabilized power supply, universal bridge, multi-digit digital multimeter, signal generator, LCR bridge, color TV signal source, oscilloscope probe, etc.
contact details:
Xi'an Antai Instrument Repair Center
Company website: www.agitekservice.com